Min./Max. Temperature Style

<< Click to Display Table of Contents >>

Navigation:  Reference > Dialog Windows > Styles Dialog Window >

Min./Max. Temperature Style

Description

This style is used when you are working with the Min./Max. Temperature tool.

 

Fields

General Tab

Name

Here, you define the name of the style. You cannot leave this field empty; the chosen name must be unique, i.e. not identical to another existing name. Aside from these limitations, you are free to choose any name.

Click on the language abbreviation in this field to set the name in all supported languages.

Digits

Number of decimal places or significant digits, which are to be displayed. The kind - Decimal Points or Significant - you can select using the adjacent drop down-list.

Thousands delimiter

The digits left of the decimal point will be grouped into thousands.

Show units

The appropriate units will be shown after each numerical value. The units can be adjusted in the Units tab of the Options dialog window.

Show result symbol

The appropriate symbols (dependent on the type of value) will be shown before each numerical value.

Style

Here, you determine whether the label line should be a simple or an orthogonal (right-angle bent) line.

Line

This setting group determines the properties of label lines (color, style, size and type).

Note that some of the lines cannot be shown when their thickness exceeds 0.394 mm.

End Point Markers

Here, you can determine how the end of both label lines should look like. There are two drop down lists that show the different possibilities.

Extended Tab

Temperature

If this option is activated, the minimal surface temperature is displayed. At least one option of the group "Shown Properties" has to be selected.

fRSi-Value

If this option is activated, the fRSi-factor is shown additionally to the minimal surface temperature. At least one option of the group "Shown Properties" has to be selected.

Surface humidity

If this option is activated, the surface humidity is shown additionally to the minimal surface temperature. At least one option of the group "Shown Properties" has to be selected.

Room humidity for condensation

If this option is activated, the room humidity for condensation is shown additionally to the minimal surface temperature. At least one option of the group "Shown Properties" has to be selected.

Room humidity for moisture

If this option is activated, the room humidity for moisture is shown additionally to the minimal surface temperature. At least one Option of the group "Shown Properties" has to be selected.

Condensation zone

If this option is activated, a condensation zone will be displayed with a unique line style - only if a condensation zone is present. The properties of the polyline you can adapt in the setting group line properties (Of: Condensation zone).

Moisture zone

If this option is activated, zones where the surface humidity exceed the critical humidity will be displayed with a unique line style - only if this zone is present. The properties of the polyline you can adapt in the setting group line properties (Of: Moisture zone). The critical surface humidity you can define in the Properties flyout of the min./max. temperaturobject.

Maximum temperature

If this option is activated then the maximum temperature is shown next to the minimum temperature.

Average temperature

If this option is activated then the average temperature will be shown next to the minimum temperature.

Line properties

This setting group determines the properties of the surface edge line, the condensation zone and the moisture zone (color, style, size and type). The line kind you can select using the Of: drop down-list.

Note that some of the lines cannot be shown when their thickness exceeds 0.394 mm.

Font Tab